Pressure control
Hydraulic actuators (high torque)
(Rated value: 100 Nm to 6,500 Nm)
Actuators that use hydraulic power to output high torque, and operate quickly at high operating speed.
They are mainly used to operate large valves in steel and sewage-treatment plants, such as blow-off valves and inlet vanes.
Pressure-sensitive part electric type
Hydraulic actuators operated by the instruction of external instrumentation signal (4-20 mA).
Type using electromagnetic valve as switching part
This type switches hydraulic circuits using an electromagnetic valve.
●Features
The unloaded hydraulic circuit system reduces oil temperature rise and slows deterioration of hydraulic oil.
The number of parts that require maintenance is few, making maintenance and inspections easier.
Good operation accuracy due to electric control.
HOP series
Maximum torque: 100 Nm to 10,000 Nm
Compact actuator with E/E positioner, hydraulic channel switching valve, hydraulic pump, cylinder, etc.
SST series
Maximum torque: 1,500 Nm to 4,500 Nm
Developed by upgrading the HOP series hydraulic actuator with solenoid operated selector valve to higher-speed, higher-accuracy and higher-torque actuator
Type using jet pipe as switching part
This type switches hydraulic circuits using a jet pipe.
●Features
The full-load hydraulic circuit system keeps output torque constant regardless of load (pressing is possible when fully closed).
Smooth operation, and constant holding and operating torque
Relatively resistant to hydraulic oil contamination.
EOP series
Maximum torque: 300 Nm to 10,000 Nm
Actuator capable of receiving instrumentation signals such as 4-20 mA and bringing out mechanical motion as rotation of the operation axis or rectilinear motion of the axis in proportion to the instrumentation signals.
SOP series
Maximum torque: 300 Nm to 10,000 Nm
High precision and quick response enabled via a servo system incorporating electrical feedback and a servo amplifier instead of a mechanical restoration mechanism.
Pressure-sensitive part direct-pressure type
Hydraulic actuators that operate by receiving the signals necessary for control with a built-in diaphragm.
Type using jet pipe as switching part
This type switches hydraulic circuits using a jet pipe.
●Features
The full-load hydraulic circuit system keeps output torque constant regardless of load (pressing is possible when fully closed).
Smooth operation, and constant holding and operating torque
Relatively resistant to hydraulic oil contamination.
COP series
Maximum torque: 300 Nm to 10,000 Nm
Receives the signals necessary for control with a pressure diaphragm to directly control the jet pipe.
Smooth operation with no control delay.
Electric actuators (low torque)
(Rated value: 20 Nm or less to 50 Nm)
Actuators using AC or DC motors
They are mainly used to control air conditioning dampers and small valves.
Pressure-sensitive part direct-pressure type
Electric actuators operated by the instruction of external instrumentation signal (4-20 mA) or single-phase AC power supply
CMP series
Maximum torque: 20 Nm
Positioning motor that receives instrumentation signals such as 4-20 mA, and operates in proportion to the signals.
Power-supply voltage: AC100V/AC200V
EEP series
Maximum torque: 20 Nm to 50 Nm
Electric actuator operated by single-phase AC power supply
It is used in combination with a PEC series controller.
Power-supply voltage: AC24V/AC100V/AC200V
Pressure-sensitive part direct-pressure type
Electric actuators that control dampers and valves by inputting room pressure or furnace pressure to the built-in pressure sensor
PEC-X series
Maximum torque: 20 Nm to 50 Nm
Linkage-connected type actuator that control differential pressure between rooms such as clean rooms
Digital control device with built-in microcomputer
Power-supply voltage: AC24V/AC100V/AC200V
RDP series
Maximum torque: 20 Nm to 50 Nm
Wall-mounted type actuator that controls differential pressure between rooms
The damper has built-in motor, pressure sensor, pressure indicator, and control board.
Power-supply voltage: AC100V
PEC-S series
Maximum torque: 20 Nm to 50 Nm
Actuator directly connected to shaft that controls differential pressure in clean rooms and manufacturing equipment
Power-supply voltage: DC24V/AC100V/AC200V
PEC-50 series
Maximum torque: 20 Nm to 50 Nm
Linkage-connected type actuator used mainly for furnace pressure control
Analog control device
Power-supply voltage: AC100V/AC200V
Additional devices
Additional devices used to control actuators